Product Overview
Approved by the United States FDA and the Korean MFDS (Ministry of Food and Drug Safety), Volnewmer employs 6.78MHz monopolar radiofrequency to deliver deep, targeted thermal precision technology. This innovative approach stimulates collagen regeneration in both the upper and lower dermis, effectively improving skin laxity by firming and tightening the skin.
Our Core Technology
Volnewmer uses 6.78MHz monopolar radio frequency technology, which consists of a single electrode to deliver targeted electrical energy deep into the skin. Our technology precisely targets both the papillary and reticular dermis, while safeguarding the epidermis. This double depth approach triggers greater tissue coagulation and new collagen production.
- STEP 1
- Place the treatment tip on skin.
- STEP 2
- The tip automatically performs an impedance check, activates the cooling system, and then delivers precise thermal energy shots.
- STEP 3
- RF thermal energy penetrates from the papillary dermis to the reticular dermis, while continuous contact cooling safeguards the epidermis.
- STEP 4
- Volnewmer stimulates collagen fiber contraction, enhancing skin elasticity and resulting in a firmer, tighter appearance.
The Science Within
Single Pulse & Real Time Impedance Detection
- Delivers full shots to the papillary and reticular dermis,
- generating double depth collagen
Continuous Water-Cooling
- Reduces patient pain while delivering targeted thermal precision.
- Water cooling system optimizes RF thermal energy accumulation.
Curved & Tilted Tip Head
- Provides fast and easy treatment for operators to treat curved skin surface.
4 Different Tips
- Enables operators to customize treatment designs to meet theds of any patient
I Tip (Eyes)
0.25cm²
- Fine tip to precisely target sensitive areas such as the eyes, nose, and marionette lines.
F Tip (Face Contouring)
3.0cm²
- A specialized tip enhances jawline and chin contours for a more defined facial profile.
V Tip (Face)
4.0cm²
- Main tip for face tightening and lifting.
S Tip (Body)
16.0cm²
- Large tip to address body parts including abdomen, arms and thighs.
Hidden Edge Technology
- Eliminates energy concentration at the edge of tip to ensure patient safety. The edges of the electrodes are positioned inside the tip structure and the tip edges are slightly lifted to eliminate contact with the skin.
Clinical outcomes
Product Specifications
Type | Electrosurgical unit |
FDA Approval | K240248 |
System Type | Monopolar RF |
Handpieces | Two |
Radio Frequency | 6.78MHz |
Rated voltage, frequency | 220~240VAC, 50/60Hz |
Power Consumption | 1600VA |
Treatment Range | Max 16㎠ |
Tips | 4types: I Tip 0.25㎠, F Tip 3.0㎠, V Tip 4.0㎠, S Tip 16.0㎠ |
Dimension | 466X567X1527mm (WXDXH) |
Weight | 56Kg (Include cooling water) |
Resistance value | 75~400Ω |
Power | 400W |
Screen size | 10.1 inch, LCD touch screen |